Navigation und Service

Zielgruppeneinstiege

Hinweis zur Verwendung von Cookies

Mit dem Klick auf "Erlauben" erklären Sie sich damit einverstanden, dass wir Ihren Aufenthalt auf der Seite anonymisiert aufzeichnen. Die Auswertungen enthalten keine personenbezogenen Daten und werden ausschließlich zur Analyse, Pflege und Verbesserung unseres Internetauftritts eingesetzt. Weitere Informationen zum Datenschutz erhalten Sie über den folgenden Link: Datenschutz

OK

Abstract zur Publikation: Rapid quantification and differentiation of human polyomavirus DNA in undiluted urine from patients after bone marrow transplantation

Biel SS, Held TK, Landt O, Niedrig M, Gelderblom HR, Siegert W, Nitsche A (2000): Rapid quantification and differentiation of human polyomavirus DNA in undiluted urine from patients after bone marrow transplantation
J. Clin. Microbiol. 38 (10): 3689-3695.

A combined PCR assay was developed for the detection and typing of human polyomavirus (huPoV) in clinical samples, consisting of (i) a qualitative seminested PCR assay (snPCR) to discriminate between huPoV BK and JC and (ii) a high-throughput, quantitative TaqMan PCR assay (TM-PCR) for the general detection of huPoV. The TM-PCR detects huPoV DNA in a linear range from 10 sup(7) to 10 sup(1) copies per assay. In reproducibility runs, the inter- and intra-assay variabilities were <=60 and <=50%, respectively. The snPCR assay uses a set of four primers for the same region of the BK and JC viral genomes. In the first round of amplification, two general primers were used, in the second round, one of these general primers and two additional, BK- or JC-specific primers were used simultaneously to produce amplicons of different sizes specific for BK virus (246 bp) and JC virus (199 bp), respectively. We tested different urine dilutions in order to determine the inhibitory effects of urine on PCR amplification. Furthermore, we compared the use of native urine with DNA purified by different preparation procedures. Our results show, that a 1:10 dilution of the urine led to complete reduction of the amplification inhibition found with 6% of undiluted urine samples. In a clinical study including 600 urine specimens, our assay turned out to be fast, cheap, and reliable in both qualitative and quantitative aspects.

Zusatzinformationen

Gesundheits­monitoring

In­fek­ti­ons­schutz

Forschung

Kom­mis­sio­nen

Ser­vice

Das Robert Koch-Institut ist ein Bundesinstitut im Geschäftsbereich des Bundesministeriums für Gesundheit

© Robert Koch-Institut

Alle Rechte vorbehalten, soweit nicht ausdrücklich anders vermerkt.