Mit dem Klick auf "Erlauben" erklären Sie sich damit einverstanden, dass wir Ihren Aufenthalt auf der Seite anonymisiert aufzeichnen. Die Auswertungen enthalten keine personenbezogenen Daten und werden ausschließlich zur Analyse, Pflege und Verbesserung unseres Internetauftritts eingesetzt. Weitere Informationen zum Datenschutz erhalten Sie über den folgenden Link: Datenschutz

OK

Abstract zur Publikation: Quality control assessment for the serological diagnosis of tick borne encephalitis virus infections

Niedrig M, Avsic T, Aberle SW, Ferenczi E, Labuda M, Rozentale B, Donoso Mantke O (2007): Quality control assessment for the serological diagnosis of tick borne encephalitis virus infections
J. Clin. Virol. 38: 260-264, Jan 29 Epub ahead of print.

BACKGROUND: The diagnosis of tick borne encephalitis (TBE) is mainly based on the demonstration of specific antibodies in serum when neurological disease is manifested. Improving diagnostics is the most important step in detecting and dealing with these pathogens. Quality control measures are essential for TBE diagnosis. OBJECTIVE: To assess an external quality assurance (EQA) program for the serologic diagnosis of TBE infections. STUDY DESIGN: A panel of 12 serum samples was sent out to be tested for the presence of TBE virus-specific IgM and IgG. This panel contained seven TBE-positive samples for IgM and/or IgG; three negative samples; two samples positive either for West Nile virus (WNV) or Dengue virus (DENV). RESULTS: Fourty-two laboratories from 25 European and 2 non-European countries participated in this EQA. The correct answer by each laboratory for all samples ranked between 58 and 96% and sera with IgM antibody positive for TBE were correctly recognized by 46-88% of the laboratories. Sera with IgG antibody positive for TBE were correctly recognized by 83-95% of the laboratories. False TBE-positive results were obtained with DENV, WNV or negative sera only for IgG-based assays. CONCLUSION: Correct results for at least 90% of the samples were obtained by 33 of 40 participating laboratories for IgM and for 16 of 42 laboratories for IgG.

Zusatzinformationen

Gesundheits­monitoring

In­fek­ti­ons­schutz

Forschung

Kom­mis­sio­nen

Ser­vice

Das Robert Koch-Institut ist ein Bundesinstitut im Geschäftsbereich des Bundesministeriums für Gesundheit

© Robert Koch-Institut

Alle Rechte vorbehalten, soweit nicht ausdrücklich anders vermerkt.