Mit dem Klick auf "Erlauben" erklären Sie sich damit einverstanden, dass wir Ihren Aufenthalt auf der Seite anonymisiert aufzeichnen. Die Auswertungen enthalten keine personenbezogenen Daten und werden ausschließlich zur Analyse, Pflege und Verbesserung unseres Internetauftritts eingesetzt. Weitere Informationen zum Datenschutz erhalten Sie über den folgenden Link: Datenschutz

OK

Abstract zur Publikation: Comparison of hemagglutination inhibition assay, an ELISA-based micro-neutralization assay and colorimetric microneutralization assay to detect antibody responses to vaccination against influenza A H1N1 2009 virus

Grund S, Adams O, Wählisch S, Schweiger B (2010): Comparison of hemagglutination inhibition assay, an ELISA-based micro-neutralization assay and colorimetric microneutralization assay to detect antibody responses to vaccination against influenza A H1N1 2009 virus
J. Virol. Methods: Epub Dec 10.

The hemagglutination inhibition (HI) assay has been the main method used to investigate immune responses to vaccination against influenza H1N1 (2009) virus. However microneutralization tests (MNT) have been shown to be more sensitive and more specific. In this study, the three methods of choice: (i) the HI assay, (ii) an ELISA-based conventional MNT and (iii) a colorimetric MNT in terms of their ability to detect antibody responses in serum pairs collected from 43 healthy individuals before and 21 days after vaccination were compared. The colorimetric MNT was established yielding intra- and inter-run imprecisions of 7.5% and 12.4%, respectively. Testing of antisera to seasonal influenza viruses demonstrated the assay to be specific for antibodies to influenza H1N1 (2009) virus. A good correlation between the three methods was found, being highest for the ELISA-MNT and the colorimetric MNT (r = 0.714 for geometric mean titers (GMT) and r = 0.695 for titer increases). Similar rates of fourfold titer increases were detected: 95.3% in the ELISA-MNT vs. 93.0% in colorimetric MNT and 95.3% in HI assay. The ELISA-based MNT demonstrated the highest titer range leading to the highest postvaccination GMT and the highest titer increase (>50-fold). The lowest GMTs were measured with the HI assay, while the colormetric MNT detected the highest GMT in prevaccination sera. Taken together, similar seroconversion rates were obtained with the three assays. The ELISA-MNT appeared to be the best method to compare absolute pre- and postvaccination GMTs. The colorimetric MNT, being less labour-intensive than the ELISA-MNT, seems to be a suitable tool in vaccination studies.

Zusatzinformationen

Gesundheits­monitoring

In­fek­ti­ons­schutz

Forschung

Kom­mis­sio­nen

Ser­vice

Das Robert Koch-Institut ist ein Bundesinstitut im Geschäftsbereich des Bundesministeriums für Gesundheit

© Robert Koch-Institut

Alle Rechte vorbehalten, soweit nicht ausdrücklich anders vermerkt.