Navigation und Service

Zielgruppeneinstiege

Hinweis zur Verwendung von Cookies

Mit dem Klick auf "Erlauben" erklären Sie sich damit einverstanden, dass wir Ihren Aufenthalt auf der Seite anonymisiert aufzeichnen. Die Auswertungen enthalten keine personenbezogenen Daten und werden ausschließlich zur Analyse, Pflege und Verbesserung unseres Internetauftritts eingesetzt. Weitere Informationen zum Datenschutz erhalten Sie über den folgenden Link: Datenschutz

OK

Abstract zur Publikation: Multiplex detection of microbial and plant toxins by immunoaffinity enrichment and matrix-assisted laser desorption/ionization mass spectrometry

Kull S, Pauly D, Störmann B, Kirchner S, Stämmler M, Dorner MB, Lasch P, Naumann D, Dorner BG (2010): Multiplex detection of microbial and plant toxins by immunoaffinity enrichment and matrix-assisted laser desorption/ionization mass spectrometry
Anal. Chem. 82 (7): 2916-2924.

Plant and microbial toxins such as ricin, staphylococcal enterotoxin B (SEB), and the botulinum neurotoxins (BoNT) are considered as potential biological warfare agents. Specific screening methods are, therefore, required that enable unambiguous and sensitive identification of these biohazards, particularly for the occurrence of the toxins in complex sample matrixes. The present study describes a combination of a multiplex-immunoaffinity purification approach, followed by matrix-assisted laser desorption/ionization (MALDI)-based detection for the simultaneous identification of ricin, SEB, BoNT/A, and BoNT/B. The method comprises an affinity enrichment step, using specific monoclonal antibodies for each of the four toxins which have been selected from a pool of antibodies. The selected antibodies allow for specific and simultaneous capture of ricin, SEB, BoNT/A, BoNT/B, and the corresponding BoNT complexes. These were subsequently identified by MALDI time-of-flight (TOF) mass spectrometry (MS), following tryptic digest. The sensitivity of the technique was approximately 500 fmol for each of the toxins. These toxins were detectable within 8 h, even when present in complex matrixes such as milk or juice. Furthermore, the MALDI-based multiplex assay allowed for the discrimination of closely related BoNT sero- and subtypes, including a real case of food-borne botulism in Germany.

Zusatzinformationen

Gesundheits­monitoring

In­fek­ti­ons­schutz

Forschung

Kom­mis­sio­nen

Ser­vice

Das Robert Koch-Institut ist ein Bundesinstitut im Geschäftsbereich des Bundesministeriums für Gesundheit

© Robert Koch-Institut

Alle Rechte vorbehalten, soweit nicht ausdrücklich anders vermerkt.